QLT-001 Β· v3Current approvedEffective 2026-09-01Owner: Quality Leadquality

PX-20 dimensional inspection

Sampling

PX-20 outer diameter is 20.00 mm with tolerance Β±0.10 mm. The allowed interval is 19.90–20.10 mm inclusive. Inspect five parts at batch start and five parts every 60 minutes while the batch runs. Record individual measurements, time, batch ID, and inspector on QF-20.

QLT-001:v3:Sampling

Failure

If any inspected part is outside the allowed interval, place the affected batch on quality hold and contact the quality lead. The quality lead determines the affected scope and disposition; the assistant cannot release product or authorize shipment.

QLT-001:v3:Failure

Version comparison β€” CHG-001

Old (v2)New (v3, effective 2026-09-01)
[βˆ’] PX-20 outer diameter is 20.00 mm with tolerance Β±0.10 mm. Inspect five parts at batch start and five parts every 120 minutes while the batch runs. Record individual measurements, time, batch ID, and inspector on QF-20.[+] PX-20 outer diameter is 20.00 mm with tolerance Β±0.10 mm. The allowed interval is 19.90–20.10 mm inclusive. Inspect five parts at batch start and five parts every 60 minutes while the batch runs. Record individual measurements, time, batch ID, and inspector on QF-20.

Sampling interval changed from 120 minutes to 60 minutes. Ingestion: indexed. Open v2